s# Station IMEI Project Last Update (UTC) Firm Batt Diag Brd Heat XSen HThr Cold Hot RSSI PCyc CREG Temp RUD QST QQV SEN IRD
501 501 Temp_2020_Testing 2020-08-07, 15:06:10 V1.0.2330 13.24V 0 4,0,0 On -40C 0C 0C 5 35 5 22°C SBD Mode 1h 1h 5m 1h
505 505 Temp_2020_Testing 2020-08-05, 18:51:59 V1.0.2330 13.88V 0 4,0,0 On -40C 0C 0C 5 244 5 22°C SBD Mode 1h 1h 1d 1h
511 511 Temp_2020_Testing 2020-08-07, 15:11:56 V1.0.2330 13.21V 0 4,0,0 On -40C 0C 0C 5 32 5 21°C SBD Mode 1h 1h 1d 1h
569 569 Temp_2020_Testing 2020-08-05, 18:51:58 V1.0.2330 13.9V 0 4,0,0 On -40C 0C 0C 5 240 7 22°C SBD Mode 1h 1h 1d 1h